How to use this matrix
Simply find your oscilloscope listed in the below table and reference the bandwidth and capacitance value. Match the bandwidth and capacitance values of your oscilloscope to the compatibility tables of our TEX series probes shown.
|
Manufacturer
|
Model
|
Bandwidth
|
Capacitance
|
|
Agilent(HP)
|
1200B
|
DC-500kHz
|
20pF
|
|
Agilent(HP)
|
1201B
|
DC-500KHz
|
20pF
|
|
Agilent(HP)
|
1205B
|
DC-500kHz
|
20pF
|
|
Agilent(HP)
|
1220A
|
DC-15MHz
|
30pF
|
|
Agilent(HP)
|
1222A
|
DC-15MHz
|
30pF
|
|
Agilent(HP)
|
1715A
|
DC-200MHz
|
11pF
|
|
Agilent(HP)
|
1722B
|
DC-275MHz
|
11pF
|
|
Agilent(HP)
|
1725A
|
DC-275MHz
|
11pF
|
|
Agilent(HP)
|
1727A
|
DC-275MHz
|
11pF
|
|
Agilent(HP)
|
1740A
|
DC-100MHz
|
20pF
|
|
Agilent(HP)
|
1742A
|
DC-100MHz
|
20pF
|
|
Agilent(HP)
|
1743A
|
DC-100MHz
|
20pF
|
|
Agilent(HP)
|
1744A
|
DC-100MHz
|
20pF
|
|
Agilent(HP)
|
5180T
|
DC-10MHz
|
35pF
|
|
Agilent(HP)
|
5180U
|
DC-10MHz
|
35pF
|
|
Agilent(HP)
|
5183T
|
DC-200MHz
|
45pF
|
|
Agilent(HP)
|
5183U
|
DC-200MHz
|
45pF
|
|
Agilent(HP)
|
54111D
|
DC-500MHz
|
6.5pF
|
|
Agilent(HP)
|
54200A
|
DC-50MHz
|
14pF
|
|
Agilent(HP)
|
54200D
|
DC-50MHz
|
14pF
|
|
Agilent(HP)
|
54201A
|
DC-300MHz
|
10pF
|
|
Agilent(HP)
|
54201D
|
DC-300MHz
|
10pF
|
|
Agilent(HP)
|
54501A
|
DC-100MHz
|
16pF
|
|
Agilent(HP)
|
54503A
|
DC-500MHz
|
7pF
|
|
Agilent(HP)
|
54504A
|
DC-400MHz
|
7pF
|
|
Agilent(HP)
|
54520A
|
DC-500MHz
|
7pF
|
|
Agilent(HP)
|
54522A
|
DC-500MHz
|
7pF
|
|
Agilent(HP)
|
54540A
|
DC-500MHz
|
7pF
|
|
Agilent(HP)
|
54542A
|
DC-500MHz
|
7pF
|
|
Agilent(HP)
|
54601B
|
DC-100MHz
|
13pF
|
|
Agilent(HP)
|
54600B
|
DC-100MHz
|
13pF
|
|
Agilent(HP)
|
54602B
|
DC-150MHz
|
13pF
|
|
Agilent(HP)
|
54603B
|
DC-60MHz
|
20pF
|
|
Agilent(HP)
|
54610B
|
DC-500MHz
|
9pF
|
|
Agilent(HP)
|
54615B
|
DC-500MHz
|
9pF
|
|
Agilent(HP)
|
54616B
|
DC-500MHz
|
9pF
|
|
Agilent(HP)
|
54616C
|
DC-500MHz
|
9pF
|
|
Agilent(HP)
|
54642A
|
DC-500MHz
|
13pF
|
|
Agilent(HP)
|
54642D
|
DC-500MHz
|
13pF
|
|
Agilent(HP)
|
54645A
|
DC-500MHz
|
13pF
|
|
Agilent(HP)
|
54810A
|
DC-500MHz
|
8pF
|
|
Agilent(HP)
|
54820A
|
DC-500MHz
|
8pF
|
|
Agilent(HP)
|
54825A
|
DC-500MHz
|
8pF
|
|
Agilent(HP)
|
54845A
|
DC-1.5GHz
|
12pF
|
|
Compensation Range
|
|
|
TEX40
|
Fixed x1, 30pF
|
|
TEX60
|
Adjustable; 10 to 50pF
|
|
TEX100
|
Adjustable; 10 to 50pF
|
|
TEX150
|
Adjustable; 5 to 30pF
|
|
TEX250
|
Adjustable; 10 to 35pF
|
|
TEX150RA
|
Adjustable; 5 to 30pF
|
|
TEX200RA
|
Adjustable; 5 to 30pF
|
|
TEX300RA
|
Adjustable; 10 to 35pF
|
|
TEX500RA
|
Adjustable; 10 to 35pF
|
|
Bandwidth
|
|
|
TEX40
|
Fixed x1, DC to 40 MHz
|
|
TEX60
|
x1:x10, DC to 60 MHz
|
|
TEX100
|
x1:x10, DC to 100 MHz
|
|
TEX150
|
x1:x10, DC to 150 MHz
|
|
TEX250
|
x1:x10, DC to 250 MHz
|
|
TEX150RA
|
RA, x10, DC to 150 MHz
|
|
TEX200RA
|
RA, x10, DC to 200 MHz
|
|
TEX300RA
|
RA, x10, DC to 300 MHz
|
|
TEX500RA
|
RA, x10, DC to 500MHz
|
Tyrosys Corp
406 N. Center Street | Bonham, Texas 75418
Phone: 903-640-4900 | Lobby Hours: 9 am to 6 pm Monday - Friday
Tyrosys Corp is PCI-DSS Compliant
Site content is copyrighted, Tyrosys Corporation © 2002-2012
|
|
|